Ground-water heat pump 12 kW GWHP12

21 842 RON

  • Thermal power: 12 kW
  • Fixed speed compressor.
  • Recommended source temperature: +6theC … +30theC.
  • Ambient temperature range from -50°C the +43 ℃.
  • Heating, cooling and hot water all year round.
  • Energy efficiency level A+++, 4.80 COP.
  • Purpose: heating, cooling homes from 70 to 180 m²

The heat pump can be custom-made in the following configurations:

  1. Refrigerant R1234yf with flow temperature of +75 ℃.
  2. Refrigerant R1234ze with flow temperature of +85 ℃.
  3. Refrigerant R407 with flow temperature of +60 ℃.

Contact us before purchase for clarification.

Made in Moldova


 

1 in stock (can be backordered)


Ground-water heat pump 12 kW GWHP12

— reliable solution for home and office

Energy and environmental efficiency

Ground-water heat pump 12 kW GWHP12 is one of the most efficient for heating, cooling and domestic hot water. Ground-to-water heat pump 12 kW GWHP12 using geothermal energy — renewable resource, available in any climate, it allows you to reduce energy costs by up to 75%. Thanks to its stable operation, regardless of the outdoor temperature, the 12 kW GWHP12 ground-to-water heat pump is ideal for homes and commercial properties up to 180 m².


Main advantages

  1. Maximum efficiency:
    • Coefficient of performance (COP) up to 4.9, ensuring rapid recovery of investment.
    • Temperature resistance from -50°C up to +45°C, guaranteeing reliability in any climatic conditions.
  2. Flexibility and adaptability:
    • Fixed power: stable operation with 12 kW performance for simplicity and reliability.
  3. Environmental safety:
    • Safe refrigerant R422D / R417A  / R22 / R407 (or on request – refrigerant R32 / R290 / R1234 – reduces environmental impact).
    • Geothermal energy minimizes the carbon footprint, contributing to a sustainable future.

Housing options

  • Compact version: intended for confined spaces.
  • Standard housing: facilitates assembly and maintenance, maintaining high performance.

Technical features

ParameterFixed power
Power12 kW
COP coefficientUp to 4.8
Heating surfaceUp to 180 m²
RefrigerantR22 / R407
Temperature rangeFrom the -50°C up to +45°C
Noise levelUp to 50 dB

Why do people choose a 12 kW GWHP12 ground-to-water heat pump?

  • Energy efficiency: The use of renewable resources considerably reduces costs.
  • Versatility: Suitable for private homes and commercial buildings, ensuring comfort all year round.
  • Ecological: Reduced environmental impact.
  • Durability: The heat pump with two compressors has high reliability and a lifespan of over 20 years.

Contact us for consultation!

Invest in innovative solutions for your home or business. The 12 kW GWHP12 ground-to-water heat pump represents energy efficiency, comfort and reliability.


How to order?

📞 Contact us for advice and to choose the right model! We will help you invest in an environmentally friendly and energy-efficient solution for your home or business.

See another model


Вес96 кг
Heat pump type

Compressor

Thermal power, kW

Heating surface, m²

Water temperature, ℃

Refrigerant

Mains power supply

Vapor injection

Working method

, ,

Model

Environment temperature, ℃

-30

Building type

Private house, Data center, Hotel, Villa

charts

Click on the temperature icons to view the required data.

Download the performance table


GWHP12 Thermal power: GWHP12 fixed speed, R407. R22, R417

GWHP12 Thermal power: GWHP12 fixed speed, R407. R22, R417

Line chart. GWHP12 fixed speed, R407. R22, R417. Data table with 8 rows and 8 columns follows.

GWHP12 Thermal power
-10-505101520
606,97,558,159,059,910,8512
557,157,858,559,4510,3511,4512,9
457,48,058,959,910,912,113,85
407,68,259,2510,2511,412,6514,35
357,88,559,5510,611,813,114,85
258,058,859,8510,9512,1513,4515,2
158,39,1510,1511,312,513,8515,5

GWHP12 Power consumption: GWHP12 fixed speed, R407. R22, R417

GWHP12 Power consumption: GWHP12 fixed speed, R407. R22, R417

Line chart. GWHP12 fixed speed, R407. R22, R417. Data table with 8 rows and 8 columns follows.

GWHP12 Power consumption
-10-505101520
603,53,623,683,83,883,974,11
553,263,443,63,713,743,873,73
452,932,943,023,113,173,273,38
402,632,682,822,912,963,053,18
352,372,512,642,72,722,822,96
252,062,192,322,362,42,522,64
151,771,932,082,142,172,182,16

GWHP12 COP: Ground-to-water heat pump 12 kW GWHP12 fixed speed

GWHP12 COP: Ground-to-water heat pump 12 kW GWHP12 fixed speed

Line chart. Ground-water heat pump 12 kW GWHP12 fixed speed. Data table with 8 rows and 8 columns follows.

GWHP12 COP
-10-505101520
602,242,352,432,62,722,833,09
552,422,42,582,653,073,13,61
452,562,72,953,283,5944,39
402,72,913,23,543,954,324,7
352,873,13,463,844,314,715,1
253,493,663,994,474,975,425,86
153,893,954,55,055,646,026,35

 

Отзывы

Отзывов пока нет.

Будьте первым, кто оставил отзыв на “Pompă de căldură sol-apă 12 kW GWHP12”