Contactor CJX93P50A for heat pump compressor
Первоначальная цена составляла 570 MDL.536 MDLТекущая цена: 536 MDL. + VAT
- Circuit voltage: up to 690V.
- Network frequency: up to 60Hz.
- Control circuits: alternating or direct current (models with the letter Z support direct current).
- Control coils: voltage of 220V.
- Operating time: up to 1200 cycles per hour (category AC-3, 380/400V).
- Durability: up to 10 million switching cycles.
Нет в наличии
Contactor CJX93P50A for heat pump compressor
This Contactor CJX93P50А with working voltage 230V/AC3 50Hz is designed for a nominal current of 50A. When voltage is applied to the control coil, the contactor switches, closing the main contacts. It is important to note that the voltage in the control circuit must be 230V. This contactor is suitable for starting compressors heat pumps with fixed speed. It can also be used as a switch for high-power peripheral equipment, such as circulation pumps, electric heaters and other equipment.
CJX93P50A contactor for compressor. Nominal characteristics conversion table
Working voltage | Rated current | Power | ||
Contactor CJX93P50А | AC-1 | AC-3 | AC-4 | AC-3 |
220/230 V, 50 Hz | 50 A | 32 A | 32 A | 7,5 kW |
380/400 V, 50 Hz | – | 32 A | 32 A | 15 kW |
660/690 V, 50 Hz | – | 22 A | 22 A | 18,5 kW |
Nominal characteristics depending on load
The connected load and the supply voltage directly influence the rated characteristics of the contactor. For example, the rated current 50A, indicated on the housing and in the device name, refers to standard use — control of electric motors with three-phase 380V power supply in the category AC-3.
Task categories
This CJX93P50A Contactor for Heat Pump Compressor is designed for a standard load of 22 kWFor less demanding applications, such as incandescent bulbs or electric resistances (TENs), the most suitable category is AC-1. On the other hand, if the device controls motors with heavy mechanisms or changes in the direction of rotation, the category is preferable. AC-4.
Contact and magnet construction
CJX93P50A contactor for heat pump compressor uses the classic double-break scheme. In addition, the central moving part is equipped with a spring to increase reliability. The manufacturers have provided for the fastening of the magnetic plates in 12 places, six of which are by hammering, to increase the strength of the construction. To reduce vibrations, rubber dampers have been added to the fixed part, and the over-tightened coils prevent the armature from rebounding when the phase crosses zero.
Auxiliary contacts NC1
In control circuits, where currents and voltages are low, switching can be difficult due to the oxide film on the contacts. During switching, the spring-loaded moving part moves, cleaning the top layer of the contacts. As a result, the perpendicular markings increase friction and provide even more effective cleaning.
CJX9 contactor series
CJX9 series contactors are very popular due to their reliable construction based on proven solutions. In addition, these devices are excellent for switching electrical circuits in various industrial equipment.
If you combine the CJX93P50A contactor for heat pump compressor with thermal relays, you can protect electrical equipment from overload. The series covers a wide range of rated currents, from 9 to 95A, and offers functional expansion through additional modules:
- Time delay contactor;
- Reversible;
- Electromagnetic starting relays;
- Contactor for KRM circuits;
- Multifunctional star-delta starters.
Technical features
- Circuit voltage: up to 690V.
- Network frequency: up to 60Hz.
- Control circuits: alternating or direct current (models with the letter Z support direct current).
- Control coils: voltage of 220V.
- Operating time: up to 1200 cycles per hour (category AC-3, 380/400V).
- Durability: up to 10 million switching cycles.
Thanks to these features, the CJX93P50A Contactor for heat pump compressor ensures reliable and efficient operation, according to modern standards.