Softstarter for heat pump ACS-R90KM6–40A
Первоначальная цена составляла 897 lei.823 RONТекущая цена: 823 lei.
Model ACS-R90KM6–40A:
- Rated voltage: 220V AC single phase
- Voltage range: 187–266V AC
- Maximum continuous voltage: 266V AC
- Maximum continuous current: 30A
- Current limitation: 30A / 1 minute
- Curent maxim de pornire: 170A (<20 ms)
- Curent maxim de impuls: 120A (<350 ms)
- Soft start time: 1 ±0.5 seconds
- Consum de energie: <15VA
Softstarter for heat pump ACS-R90KM6–40A
ACS-R90KM6–40A is designed for controlled starting of single-phase compressors used in heat pumps, thermodynamic boilers, chillers and HVAC systems. The device reduces starting current and minimizes electrical and mechanical shocks to the compressor.
By using a heat pump softstarter, the ACS-R90KM6–40A Softstarter operates more stably, wear on electrical components is reduced, and the service life of the equipment is considerably increased.
Technical features
- Soft start for single-phase 220V compressors
- Starting current reduction by up to 70%
- Compatible with 4HP and 5HP heat pumps
- Electrical overload protection
- Contactor bypass integrat
- Automatic restart protection
- Compact and durable housing
- Quick installation in HVAC and refrigeration systems
Benefits of use
- Reduction of current peaks when starting the compressor
- Protecting the electrical grid and generator
- Reducing vibrations and mechanical shocks
- More stable heat pump operation
- Increasing compressor life
- Reducing the risk of voltage drop
Where to use
The ACS-R90KM6–40A heat pump soft starter can be used in:
- air-to-water heat pumps;
- heat pump boilers;
- compact chiller;
- residential HVAC systems;
- single-phase air conditioners;
- refrigeration equipment.
Operating principle
When a compressor starts, the current drawn can exceed several times the rated value. The ACS-R90KM6–40A heat pump soft starter controls the voltage applied to the motor during start-up and reduces the strain on the electrical installation.
This technology allows for smoother compressor start-up, eliminates electrical shocks, and contributes to the safe operation of HVAC equipment.
Protection and reliability
- Electronic overload protection
- High dielectric strength
- Anti-vibration protection
- Restart protection – 180 seconds
- Flameproof housing with epoxy sealing
- Temperature resistance between -40°C and +85°C
Construction specifications
- Dimensions: 120 × 70 × 40 mm
- Weight: approximately 200g
- Working humidity: 0–95% RH
- Simple and compact installation
The ACS-R90KM6–40A heat pump soft starter is an effective solution for protecting compressors and optimizing the operation of HVAC and refrigeration systems.