{"id":8252,"date":"2026-05-13T15:38:55","date_gmt":"2026-05-13T12:38:55","guid":{"rendered":"https:\/\/altal.md\/?post_type=product&#038;p=8252"},"modified":"2026-06-29T15:31:38","modified_gmt":"2026-06-29T12:31:38","slug":"heat-pump-controller-mch2001030","status":"publish","type":"product","link":"https:\/\/altal.md\/en\/mch2001030-controler-pentru-pompa-de-caldura\/","title":{"rendered":"MCH2001030 Heat pump controller"},"content":{"rendered":"<h2 data-section-id=\"1249cuf\" data-start=\"0\" data-end=\"91\">MCH2001030 Controller for heat pump \/ chiller Carel \u03bcC\u00b2 \/ \u03bcChiller<\/h2>\n<p data-start=\"93\" data-end=\"327\">Specialized controller for chillers and heat pumps, with integrated control logic: up to 1 refrigeration circuit, up to 2 compressors and reversible cycle support. Product <span class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"><span class=\"whitespace-normal\">Carel S.p.A.<\/span><\/span>.<\/p>\n<hr data-start=\"329\" data-end=\"332\" \/>\n<h3 data-section-id=\"p33xwj\" data-start=\"334\" data-end=\"392\">Controller for chiller and heat pump MCH2001030<\/h3>\n<p data-start=\"394\" data-end=\"571\">MCH2001030 Heat pump controller is specialized developed by <a class=\"decorated-link\" href=\"https:\/\/www.carel.com?utm_source=chatgpt.com\" target=\"_new\" rel=\"noopener\" data-start=\"448\" data-end=\"501\">Carol<\/a> for small-capacity chillers and heat pumps, including systems:<\/p>\n<ul data-start=\"573\" data-end=\"619\">\n<li data-section-id=\"1mwhxh6\" data-start=\"573\" data-end=\"583\">air-water;<\/li>\n<li data-section-id=\"qxv8n2\" data-start=\"584\" data-end=\"594\">water-water;<\/li>\n<li data-section-id=\"1ejybt8\" data-start=\"595\" data-end=\"619\">HVAC monobloc units.<\/li>\n<\/ul>\n<p data-start=\"621\" data-end=\"775\">Unlike the programmable pCO series, the controller includes integrated logic for chillers and does not require programming in the 1tool or c.suite platforms.<\/p>\n<hr data-start=\"777\" data-end=\"780\" \/>\n<h2 data-section-id=\"b2mk5h\" data-start=\"782\" data-end=\"817\">Compatible \u03bcC\u00b2 \/ \u03bcChiller series<\/h2>\n<h3 data-section-id=\"10ofu44\" data-start=\"819\" data-end=\"832\">\u03bcC\u00b2 (UCH)<\/h3>\n<p data-start=\"833\" data-end=\"871\">Basic series intended for systems with:<\/p>\n<ul data-start=\"872\" data-end=\"920\">\n<li data-section-id=\"9m0e5v\" data-start=\"872\" data-end=\"895\">1 refrigeration circuit;<\/li>\n<li data-section-id=\"1ih73ii\" data-start=\"896\" data-end=\"920\">up to 2 compressors.<\/li>\n<\/ul>\n<h3 data-section-id=\"n15uf7\" data-start=\"922\" data-end=\"940\">\u03bcChiller UCHBP<\/h3>\n<p data-start=\"941\" data-end=\"970\">The Big Platform version offers:<\/p>\n<ul data-start=\"971\" data-end=\"1075\">\n<li data-section-id=\"ze2a1u\" data-start=\"971\" data-end=\"1004\">up to 2 refrigeration circuits (optional);<\/li>\n<li data-section-id=\"iu9i6x\" data-start=\"1005\" data-end=\"1029\">up to 4 compressors (optional);<\/li>\n<li data-section-id=\"1lge4x7\" data-start=\"1030\" data-end=\"1075\">support for reversible cycle (heat pump).<\/li>\n<\/ul>\n<h3 data-section-id=\"19eg0th\" data-start=\"1077\" data-end=\"1093\">U20 \/ \u03bcC\u00b2 SE. MCH2001030 Heat pump controller<\/h3>\n<p data-start=\"1094\" data-end=\"1119\">Entry-level series for:<\/p>\n<ul data-start=\"1120\" data-end=\"1207\">\n<li data-section-id=\"1yc3xcu\" data-start=\"1120\" data-end=\"1158\">monobloc air conditioners;<\/li>\n<li data-section-id=\"1w10b0r\" data-start=\"1159\" data-end=\"1180\">DIN rail mounting;<\/li>\n<li data-section-id=\"1kaksph\" data-start=\"1181\" data-end=\"1207\">compact HVAC applications.<\/li>\n<\/ul>\n<hr data-start=\"1209\" data-end=\"1212\" \/>\n<h2 data-section-id=\"komnif\" data-start=\"1214\" data-end=\"1245\">Configuration and parameterization<\/h2>\n<p data-start=\"1247\" data-end=\"1393\">The controller configuration is done through internal parameters, the number of which can exceed 100 settings, depending on the version and firmware.<\/p>\n<p data-start=\"1395\" data-end=\"1467\">Preconfigured firmwares are loaded for specific applications:<\/p>\n<ul data-start=\"1469\" data-end=\"1574\">\n<li data-section-id=\"m1n3nj\" data-start=\"1469\" data-end=\"1490\">air-cooled chiller;<\/li>\n<li data-section-id=\"1hfny1c\" data-start=\"1491\" data-end=\"1514\">water-cooled chiller;<\/li>\n<li data-section-id=\"tarzrq\" data-start=\"1515\" data-end=\"1554\">heat pump with reversible operation;<\/li>\n<li data-section-id=\"1kwbac0\" data-start=\"1555\" data-end=\"1574\">monobloc units.<\/li>\n<\/ul>\n<p data-start=\"1576\" data-end=\"1685\">Some of the firmware is custom OEM configurations for HVAC equipment manufacturers.<\/p>\n<hr data-start=\"1687\" data-end=\"1690\" \/>\n<h2 data-section-id=\"1j1v1i2\" data-start=\"1692\" data-end=\"1722\">Monitoring and communication<\/h2>\n<p data-start=\"1724\" data-end=\"1744\">The controller supports:<\/p>\n<ul data-start=\"1746\" data-end=\"1851\">\n<li data-section-id=\"brgngf\" data-start=\"1746\" data-end=\"1781\">Modbus RTU via RS485 (optional);<\/li>\n<li data-section-id=\"1p2ubhf\" data-start=\"1782\" data-end=\"1851\">pLAN bus for integration with pCO controllers and BOSS systems.<\/li>\n<\/ul>\n<p data-start=\"1853\" data-end=\"1982\">For complex chillers, with multiple circuits and advanced control logic, it is recommended to use programmable platforms:<\/p>\n<ul data-start=\"1984\" data-end=\"2001\">\n<li data-section-id=\"1i40woh\" data-start=\"1984\" data-end=\"1992\">pCO5+;<\/li>\n<li data-section-id=\"1a7we0n\" data-start=\"1993\" data-end=\"2001\">c.pCO.<\/li>\n<\/ul>\n<hr data-start=\"2003\" data-end=\"2006\" \/>\n<h2 data-section-id=\"7ey9a4\" data-start=\"2008\" data-end=\"2061\">MCH2001030 Heat pump controller. Advantages.<\/h2>\n<ul data-start=\"2063\" data-end=\"2301\">\n<li data-section-id=\"iis9d5\" data-start=\"2063\" data-end=\"2118\">Integrated logic for chillers and heat pumps;<\/li>\n<li data-section-id=\"l6hp5n\" data-start=\"2119\" data-end=\"2157\">No additional programming required;<\/li>\n<li data-section-id=\"178b3cx\" data-start=\"2158\" data-end=\"2196\">Compatible with compact HVAC systems;<\/li>\n<li data-section-id=\"1brsi1k\" data-start=\"2197\" data-end=\"2234\">Support for multiple compressors;<\/li>\n<li data-section-id=\"1k2jryf\" data-start=\"2235\" data-end=\"2262\">Modbus and pLAN integration;<\/li>\n<li data-section-id=\"1ukyg5f\" data-start=\"2263\" data-end=\"2301\">Carel brand industrial reliability.<\/li>\n<\/ul>\n<p><span style=\"color: #0000ff;\"><strong><a style=\"color: #0000ff;\" href=\"https:\/\/altal.md\/en\/control\/\">Other controllers for heat pumps.<\/a><\/strong><\/span><\/p>\n<hr \/>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<h2><span style=\"color: #800080;\">Model: MCH2001030<\/span><\/h2>\n<ul>\n<li>Panel mounting,<\/li>\n<li>1 circuit,<\/li>\n<li>2 compressors,<\/li>\n<li>24 VAC,<\/li>\n<li>interval -15% ~ +10%;<\/li>\n<li>50\/60 Hz<\/li>\n<li>RISC microprocessor<\/li>\n<li>with real-time timer<\/li>\n<\/ul>\n<hr \/>\n<p>&nbsp;<\/p>","protected":false},"featured_media":8285,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_brand":[],"product_cat":[251,183],"product_tag":[],"class_list":["post-8252","product","type-product","status-publish","has-post-thumbnail","product_cat-controlere-pentru-pompe-de-caldura","product_cat-catalog","product_shipping_class-greutate-mica","first","instock","taxable","shipping-taxable","purchasable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product\/8252","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/comments?post=8252"}],"version-history":[{"count":0,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product\/8252\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/media\/8285"}],"wp:attachment":[{"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/media?parent=8252"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product_brand?post=8252"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product_cat?post=8252"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product_tag?post=8252"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}