{"id":2927,"date":"2025-06-16T00:28:41","date_gmt":"2025-06-16T00:28:41","guid":{"rendered":"https:\/\/altal.md\/?post_type=product&#038;p=2927"},"modified":"2026-06-29T15:40:50","modified_gmt":"2026-06-29T12:40:50","slug":"compressor-contactor-cjx93p30a","status":"publish","type":"product","link":"https:\/\/altal.md\/en\/contactor-cjx93p30a-pentru-compresor\/","title":{"rendered":"Contactor CJX93P30A for heat pump compressor"},"content":{"rendered":"<hr \/>\n<h2><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Contactor CJX93P30A for heat pump compressor<\/span><\/h2>\n<p><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">This CJX93P30A Compressor Contactor is designed for a nominal current of 30A. When voltage is applied to the control coil, the contactor is activated, closing the main contacts. It is important that the control circuit voltage is 230V. This contactor is ideal for starting compressors <a style=\"color: #000000;\" href=\"https:\/\/altal.md\/en\/heat-pump-altal\/\" target=\"_blank\" rel=\"noopener\">heat pumps<\/a> with fixed speed. It can also be used to switch high-power peripheral equipment such as circulation pumps, electric heaters and other devices.<\/span><\/p>\n<h2><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">CJX93P30A Compressor Contactor \u2013 Characteristics Conversion Table<\/span><\/h2>\n<table style=\"width: 44.8987%;\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"width: 18.8215%;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Working voltage<\/strong><\/span><\/td>\n<td style=\"width: 18.9639%; text-align: center;\" colspan=\"2\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Rated current<\/strong><\/span><\/td>\n<td style=\"width: 19.4343%; text-align: center;\" colspan=\"2\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Rated power<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 18.8215%;\"><\/td>\n<td style=\"width: 9.13422%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>AC3<\/strong><\/span><\/td>\n<td style=\"width: 9.8297%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>AC4<\/strong><\/span><\/td>\n<td style=\"width: 10.623%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>AC3<\/strong><\/span><\/td>\n<td style=\"width: 8.81127%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>AC4<\/strong><\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 18.8215%;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">50Hz, 220\/230V<\/span><\/td>\n<td style=\"width: 9.13422%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">\u2013<\/span><\/td>\n<td style=\"width: 9.8297%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">\u2013<\/span><\/td>\n<td style=\"width: 10.623%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">7,5 kW<\/span><\/td>\n<td style=\"width: 8.81127%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">\u2013<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 18.8215%;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">50Hz, 380\/400V<\/span><\/td>\n<td style=\"width: 9.13422%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">30 A<\/span><\/td>\n<td style=\"width: 9.8297%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">12 A<\/span><\/td>\n<td style=\"width: 10.623%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">15 kW<\/span><\/td>\n<td style=\"width: 8.81127%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">5,5 kW<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"width: 18.8215%;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">50Hz, 660\/690V<\/span><\/td>\n<td style=\"width: 9.13422%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">21 A<\/span><\/td>\n<td style=\"width: 9.8297%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">7,5 A<\/span><\/td>\n<td style=\"width: 10.623%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">18,5 kW<\/span><\/td>\n<td style=\"width: 8.81127%; text-align: center;\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">5,5 kW<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Nominal characteristics depending on load<\/span><\/h3>\n<p><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">The connected load and the supply voltage directly influence the performance of the contactor. The rated current of 30A, mentioned in the name Contactor CJX93P32\u0410, is intended for standard use \u2013 control of three-phase 380V electric motors, category <a style=\"color: #000000;\" href=\"https:\/\/en.wikipedia.org\/wiki\/Utilization_categories\" target=\"_blank\" rel=\"noopener\"><strong>AC-3<\/strong><\/a>.<\/span><\/p>\n<h3><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Usage categories<\/span><\/h3>\n<p><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">CJX93P30A contactor for compressors is designed for a nominal load of 15 kW. For simpler applications, such as light bulbs or electric resistors, the category is recommended. <a style=\"color: #000000;\" href=\"https:\/\/en.wikipedia.org\/wiki\/Utilization_categories\" target=\"_blank\" rel=\"noopener\"><strong>AC-1<\/strong><\/a>For controlling motors with high inertia or reversing, the category is preferred. <a style=\"color: #000000;\" href=\"https:\/\/en.wikipedia.org\/wiki\/Utilization_categories\" target=\"_blank\" rel=\"noopener\"><strong>AC-4<\/strong><\/a>.<\/span><\/p>\n<h3><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Construction of contacts and magnetic core<\/span><\/h3>\n<p><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">CJX93P30A compressor contactor uses a double-break scheme with a central spring mechanism for high reliability. The magnetic core plates are fixed at 12 points, 6 of which are reinforced with rivets for durability. Rubber dampers reduce vibration, and short-circuiting coils prevent armature recoil at phase zero crossing.<\/span><\/p>\n<h3><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Auxiliary contacts NC1<\/span><\/h3>\n<p><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">In circuits with low currents and voltages, oxidation of the contacts can make switching difficult. Auxiliary contacts <strong>NC1<\/strong> are equipped with a self-cleaning system: the spring-loaded moving part moves and mechanically cleans the contact surface. Perpendicular grooves increase the efficiency of this process.<\/span><\/p>\n<hr \/>\n<h3><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">CJX9 contactor series<\/span><\/h3>\n<p><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">The CJX9 series is recognized for its reliable design and versatility in industrial use. The contactors are suitable for switching electrical circuits in various industrial equipment. The CJX93P30A compressor contactor can be combined with thermal relays to protect electrical equipment against overloads. The series covers rated currents from 9A to 95A and offers additional options:<\/span><\/p>\n<ul>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Contactors with timing;<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Reversible contactors;<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Magnetic starters;<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Contactors for power factor compensation circuits (KRM);<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">&#034;Star-delta&#034; starter.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Technical specifications<\/span><\/h3>\n<ul>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Working voltage:<\/strong> up to 690V.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Network frequency:<\/strong> up to 60Hz.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Control circuits:<\/strong> alternating or direct current (models with the suffix Z support DC).<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Control coil:<\/strong> 220V.<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Switching cycles:<\/strong> up to 1200\/h (category <strong>AC-3<\/strong>, 380\/400V).<\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>Lifespan:<\/strong> up to 10 million cycles<\/span><\/li>\n<\/ul>\n<h2><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">FAQ about Contactor CJX93P30A for heat pump compressor<\/span><\/h2>\n<p class=\"isSelectedEnd\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>1. What is the CJX93P30A contactor used for?<\/strong><\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">The CJX93P30A contactor is used to start and stop compressors in fixed-speed heat pumps, as well as to control other high-power consumers such as circulation pumps and electric heaters.<\/span><\/p>\n<p class=\"isSelectedEnd\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>2. What voltage is required for the control coil?<\/strong><\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">The contactor control coil operates at 230V AC and must be supplied with this voltage to ensure correct operation of the main contacts.<\/span><\/p>\n<p class=\"isSelectedEnd\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>3. What is the maximum motor power that can be controlled by the CJX93P30A?<\/strong><\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">In the AC-3 category at 380\/400V, the contactor can control electric motors with a power of up to 15 kW, being suitable for most compressors used in HVAC installations and heat pumps.<\/span><\/p>\n<p><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><strong>4. Can it be used together with a thermal relay?<\/strong><\/span><br \/>\n<span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Yes. The CJX93P30A contactor is compatible with thermal relays to protect motors and compressors against overloads and abnormal operation.<\/span><\/p>\n<h2 data-section-id=\"1rdq152\" data-start=\"1958\" data-end=\"1989\"><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\">Recommended similar products<\/span><\/h2>\n<ul>\n<li style=\"list-style-type: none;\">\n<ul data-start=\"1991\" data-end=\"2145\">\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><a style=\"color: #000000;\" href=\"https:\/\/altal.md\/en\/nylon-cable-ties-3-6-x-300-mm\/\" target=\"_blank\" rel=\"noopener\">Nylon cable ties 3.6 x 300 mm 100 pcs<\/a><\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><a style=\"color: #000000;\" href=\"https:\/\/altal.md\/en\/corrugated-conduit-7-mm-black\/\" target=\"_blank\" rel=\"noopener\">7 mm black corrugated tube with probe<\/a><\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><a style=\"color: #000000;\" href=\"https:\/\/altal.md\/en\/perforated-cable-trunking-35x40x2000mm\/\" target=\"_blank\" rel=\"noopener\">PVC cable trunking 40\u00d725 mm<\/a><\/span><\/li>\n<li><span style=\"font-family: arial, helvetica, sans-serif; color: #000000;\"><a style=\"color: #000000;\" href=\"https:\/\/altal.md\/en\/tb-terminal-block-tb-1512\/\" target=\"_blank\" rel=\"noopener\">Small electrical cable fixing clips<\/a><\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><span style=\"color: #000000; font-family: arial, helvetica, sans-serif;\"><a style=\"color: #000000;\" href=\"https:\/\/altal.md\/en\/contactor-cjx93p40a\/\" target=\"_blank\" rel=\"noopener\">See another model<\/a><\/span><\/p>\n<hr \/>","protected":false},"excerpt":{"rendered":"<ul>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; color: #000000;\"><strong>Working voltage:<\/strong> up to 690V.<\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; color: #000000;\"><strong>Network frequency:<\/strong> up to 60Hz.<\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; color: #000000;\"><strong>Control circuits:<\/strong> alternating or direct current (models with the suffix Z support DC).<\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; color: #000000;\"><strong>Control coil:<\/strong> 220V.<\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; color: #000000;\"><strong>Switching cycles:<\/strong> up to 1200\/h (category <strong>AC-3<\/strong>, 380\/400V).<\/span><\/li>\n<li><span style=\"font-family: tahoma, arial, helvetica, sans-serif; color: #000000;\"><strong>Lifespan:<\/strong> up to 10 million cycles.<\/span><\/li>\n<\/ul>","protected":false},"featured_media":2161,"comment_status":"open","ping_status":"closed","template":"","meta":{"_kad_post_transparent":"default","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"default","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false},"product_brand":[198],"product_cat":[183,276,987],"product_tag":[278,455,452],"class_list":["post-2927","product","type-product","status-publish","has-post-thumbnail","product_brand-altal","product_cat-catalog","product_cat-contactoare-electrice","product_cat-produse-electrice","product_tag-278","product_tag-contactor","product_tag-pompe-de-caldura","product_shipping_class-greutate-mica","first","instock","featured","taxable","shipping-taxable","purchasable","product-type-simple","entry","content-bg","loop-entry"],"_links":{"self":[{"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product\/2927","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/comments?post=2927"}],"version-history":[{"count":0,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product\/2927\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/media\/2161"}],"wp:attachment":[{"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/media?parent=2927"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product_brand?post=2927"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product_cat?post=2927"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/altal.md\/en\/wp-json\/wp\/v2\/product_tag?post=2927"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}